TESEQ has introduced its new ITS 6006 radiated immunity test system.
The ITS 6006 consists of an integrated RF signal generator, RF switch and EUT monitoring interfaces. The unit is designed for a wide range of radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the generator, the system includes the AM and PM modulators necessary for EMC testing. Other modulators can be connected to the external modulation input of the ITS 6006. The RF signal can be switched to one of four outputs, where up to four power amplifiers can be connected directly. Additional RF switches are available for combining two amplifier paths into a single antenna connection. Two of these relays are included for the four amplifier paths.
ITS 6006 interlock outputs ensure the activation of the power amplifier for only the selected signal path. The 3.5“color display shows the generator parameters. LEDs indicate the state of further functions. The EUT monitoring is provided by six digital, one analog and one optical input, as well as four digital outputs. Up to three power meters PMR 6006 can be connected directly to the ITS 6006. The ITS 6006 provides remote control through its network, RS232 and USB interfaces.
Teseq provides a traceable calibration certificate with all of its products and accredited calibration services are also available from TESEQ calibration labs upon request.