Tuesday 6 September 2011

Reliable protection for motors and plant components

Monitoring relays with IO-Link interface

The Siemens Industry Automation Division has equipped its complete range of monitoring relays with the IO-Link interface. The relays protect motors and plant components reliably by monitoring parameters such as temperature, speed, network quality, current and voltage. The relays communicate with the control level via IO-Link to transfer, for example, measured values and messages. The Sirius 3UG48 monitoring relays for electrical and mechanical measurements monitor the observance of parameterizable limits for speed, network quality, current, power factor (cos phi) or voltage. The Sirius 3RS14 and 3RS15 temperature monitoring relays have between one and three resistance sensors or thermocouples for controlling temperatures from -99 to +1,800 degrees Celsius, and can also be used for simple control tasks . The new monitoring relays can also fulfill their monitoring tasks reliably without an IO-Link connection to a controller.

Connecting the new Sirius relay via an IO-Link to the control level facilitates efficient, central parameter assignment as well as detailed fault localization and diagnostics. This simplifies commissioning and maintenance. The devices have several LEDs and a display for showing actual values and can be used directly in the control cabinet for diagnostic purposes. The values are also displayed in the central control system via the IO-Link for simple further processing. The new Sirius relays are parameterized either directly at the device or from the central control system via the IO-Link. Data synchronization with the higher-level control system ensures that the system documentation is up-to-date at all times. New parameters are automatically assigned by a parameter server, which makes it considerably easier to replace any devices. For efficient energy management, the Sirius relays 3UG48 also support the data formats defined in the Profienergy profile.

IO-Link is a communication standard for uniformly linking sensors and switching devices to the control level by means of a cost-effective, point-to-point connection. IO-Link facilitates central fault localization and diagnostics down to sensor/actuator level, and simplifies commissioning and maintenance, because parameter data can be dynamically changed directly from the application. This helps to increase plant availability and lower engineering expenditure. As an open interface, IO-Link can be integrated into all conventional fieldbus and automation systems.

No comments:

Post a Comment