Showing posts with label Compliance. Show all posts
Showing posts with label Compliance. Show all posts

Friday, 5 March 2021

Monitoring solvent emissions to ensure compliance.

With over 40 years of experience in designing VOC analysers, Signal Group has specialised in developing instruments that enable process operators to demonstrate compliance with environmental regulations on emissions. Stephane Canadas explains the vital role of monitoring.

Governments from around the world have implemented environmental regulations to reduce the emissions of volatile organic compounds (VOCs) from industrial processes. For example, according to the European Solvents Industry Group, total VOC emissions in the EU have been reduced by more than 60% since 1990.
Background
VOCs are released from industrial activities that utilise organic chemicals such as solvents, as well as from engines and incinerators that burn organic materials and fuels. Both types of application require similar monitoring equipment, but this article will focus on those applications that involve solvents.

Solvents are used widely in the chemical industry as well as for cleaning and degreasing products and machinery, or dissolving, thinning and dispersing coatings, adhesives, paints and inks. Solvents evaporate readily at room temperature and represent a significant safety hazard in the workplace, so they are generally vented away from workers and the emissions from such vents frequently require abatement prior to release.

Solvent emissions have to be minimised because of their environmental effects, which include the formation of ozone, a constituent of photochemical smog. At ground level, ozone is generated when VOCs react with nitrogen oxides (NOx) in the presence of sunlight. Ozone can have both acute and chronic effects on humans; affecting the respiratory, cardiovascular and central nervous system, as well as reproductive health. Ground level ozone can also have harmful effects on vegetation and sensitive ecosystems.

In most countries, the emissions of regulated processes with the potential to release VOCs are issued with permits that include an emission limit for total organic carbon (TOC). The Standard Reference Method for the measurement of TOC is with a Flame Ionisation Detector (FID). In some cases, it may be necessary for the monitoring activity to speciate toxic VOCs or to distinguish between methane and non-methane VOCs

Author: Stephane Canadas, Signal Group
European VOC Solvent Emissions Directive (SED)

The main objective of the SED is to reduce the emissions of VOCs, and operators have two main compliance options. They may demonstrate compliance with a VOC emission limit value and fugitive emission limits by submitting monitoring data. This data will either include annual or continuous monitoring results depending on the size of process’s VOC emissions. Alternatively, processes may use a solvent reduction approach to achieve the results that would be obtained from meeting a mass emission limit. The reduction scheme enables the operator to attain emission reductions, equivalent to those that would have been achieved if the emission limit values were to be applied. This could be by substituting products with a high solvent content for low solvent or solvent free products and/or changing to solvent free production processes.

Under the SED, regulators require continuous monitoring where the average emission, following abatement, is more than 10 kg/h of total organic carbon. Continuous monitoring is also required where the regulator considers it necessary to demonstrate compliance with VOC emission limits. If continuous monitoring is not necessary, the regulator will require periodic measurements. For periodic measurements of VOC at least three readings must be obtained during each measurement exercise. Where there is consistent compliance with emission limits, regulators may consider reducing the monitoring frequency requirement. However, the monitoring frequency should be increased, for example, as part of the commissioning of new or substantially changed activities, or where emission levels are close to the emission concentration limits.

Clearly, VOC monitoring, both continuous and periodic, have a key role to play in demonstrating compliance. However, Signal’s customers also use FIDs to measure the effects of mitigation measures; to check the performance of abatement equipment; for process control, and to investigate diffuse emissions.

Reducing VOC emissions in the USA
In the United States, the Clean Air Act is a federal law regulating air emissions from stationary and mobile sources. The Act authorises the United States Environmental Protection Agency (US EPA) to establish National Ambient Air Quality Standards (NAAQS) to protect public health and to regulate the emissions of hazardous air pollutants. The EPA has therefore published a list of hazardous air pollutants, many of which are VOCs.

VOCs can contribute to non-attainment with the NAAQS or may adversely affect the attainment status of an area. The EPA has addressed serious violations through enforcement actions, achieving measurable pollutant reductions and improving air quality. Through partnerships with state and tribal authorities, the US EPA has conducted multiple joint inspections and joint enforcement actions, and this has resulted in a significant reduction of VOC emissions, particularly from the oil & gas sector.

In the USA, Method 25 is applicable for the determination of VOCs (measured as total gaseous non-methane organics (TGNMO) and reported as carbon) in stationary source emissions. 

The Method says: “Direct measurement of an effluent with a flame ionization detector (FID) analyzer may be appropriate with prior characterization of the gas stream and knowledge that the detector responds predictably to the organic compounds in the stream. If present, methane (CH4) will, of course, also be measured. 

The FID can be used under any of the following limited conditions:
(1) Where only one compound is known to exist;
(2) When the organic compounds consist of only hydrogen and carbon;
(3) Where the relative percentages of the compounds are known or can be determined, and the FID responses to the compounds are known;
(4) Where a consistent mixture of the compounds exists before and after emission control and only the relative concentrations are to be assessed; or
(5) Where the FID can be calibrated against mass standards of the compounds emitted (solvent emissions, for example).
Another example of the use of a direct FID is as a screening method. If there is enough information available to provide a rough estimate of the analyzer accuracy, the FID analyzer can be used to determine the VOC content of an uncharacterized gas stream. With a sufficient buffer to account for possible inaccuracies, the direct FID can be a useful tool to obtain the desired results without costly exact determination.”

Alternatively, Method 25A applies to the determination of total gaseous organic concentration of vapours consisting primarily of alkanes, alkenes, and/or aromatic hydrocarbons. The concentration is expressed in terms of propane (or other appropriate organic calibration gas) or in terms of carbon. Again, the Method stipulates the collection of a heated gas sample which is passed to a flame ionization analyser.

VOC monitoring

MiniFID 3010
As outlined above, the level of monitoring required by regulators is dictated by the scale of an operator’s VOC emissions, with continuous monitoring required for the larger emitters and discontinuous monitoring for processes with lower emissions. Signal Group has therefore developed VOC analysers to meet both requirements – a portable heated FID (Signal MiniFID 3010) for periodic measurements and a continuous heated FID (SOLAR) for permanent installations.

The continuous heated FID SOLAR analyser can be easily fitted into a 19” rack cabinet for indoor or outdoor installation. The analyser has an embedded microprocessor which automatically starts the analyser upon receipt of a command from a detachable tablet, or from a remote installation with Signal’s S4i software. This command sets in place a sequence of analyser actions which prepare the analyser to take samples and report calibrated readings to the instrument’s internal datalogger.

Using an optional detachable tablet, users are able to manage the analyser wirelessly up to 50 metres away from the analyser. In addition, using the remote S4i software over an Ethernet connection, the analyser can be operated from anywhere at any time. This remote accessibility also means that the Signal after-sales team can monitor alarms, conduct remote calibration and even troubleshoot if necessary.

The portable heated FID MiniFID 3010 is suitable for a variety of applications:
1. Compliance monitoring where the permit requires discontinuous measurements
2. Calibration of CEMS
3. Temporary back-up for CEMS
4. Checking abatement performance
5. Fugitive emissions investigations
6. Process optimisation
In contrast with most of the other ‘portable’ FIDs on the market, the MiniFID 3010 was designed as a rugged, portable field-use instrument. With an optional internal datalogger (and memory stick), sample pump, inlet filter, heated line controller and a detachable gas bottle holder, the MiniFID 3010 is ideal for use on ducts and stacks with difficult access. The analyser’s detachable bottle holder accommodates both the burner gas and the calibration gas, with zero air provided with a background hydrocarbons purifier.

The frame is made from lightweight aluminium and the instrument is supplied with lifting eyes and a comfortable shoulder strap. Portable FIDs often need to operate with extended power cables, so the MiniFID is able to operate without a power-hungry microprocessor, (110VAC or 220VAC is specified when purchasing). The heated line (optional 5m or 10m) is powered from a socket on the side of the analyser, which helps to reduce the amount of cabling required. The heated line is supplied with a stainless steel sintered filter probe for insertion into the stack or duct.

The instrument is simple to operate:
1. Switch on, wait for the temperature interlock to reach set temperature.
2. Turn gases on, press “Ignite” switch.
3. Wait for the reading to settle, select “Zero” gas and adjust dial to read zero on the analyser display.
4. Select “Span” and adjust span dial to read the value of the calibration gas.
5. Select “Sample” and the analyser will start drawing sample gas through the heated line.
6. Wait a few minutes for the sample gas to arrive at the analyser and the instrument will start to display readings, which may be logged to the memory stick for later examination and reporting.

Many MiniFID 3010 users are process operators, but a larger number are environmental consultants or test houses that provide monitoring services. This is because stack testers require instruments that are rugged, reliable and designed for field operation.

Summary
FID analysers are ideal for a variety of solvent emissions monitoring applications – the list given in Method 25 provides a useful guide. It is important to remember that while Flame Ionisation is the reference method for the monitoring of VOCs, the response of the analyser will vary according to the VOC or VOCs present in the sample.

@GasAnalysers @_Enviro_News #PAuto #Environment #Compliance #Standards

Wednesday, 16 November 2016

NEMA compliance for RTUs.

Red Lion Controls' multi-carrier 4G LTE Sixnet® series RAM® 6000 and 9000 industrial cellular RTUs have earned NEMA TS2 section 2 compliance, which validates industrial equipment for use in Intelligent Traffic Systems (ITS) applications. By providing an easy upgrade path for ITS environments without communication or unreliable landline options, Red Lion’s industrial RTUs enable system integrators, municipalities, engineering firms and network integrators to benefit from easy-to-deploy cellular connectivity.

“With the RAM 6000 and 9000 industrial cellular RTUs receiving NEMA TS2 compliance, ITS engineers now have the option of industry-leading communications equipment that operates reliably in outdoor environments,” said Colin Geis, Director of Product Management, Industrial Internet of Things (IIoT) at Red Lion Controls. “Our rugged RTUs feature some of the widest environmental specifications for operation in harsh environments. Together with the benefits of multi-carrier 4G LTE support, the RAM 6000 and 9000 are able to reliably help serve the critical area of traffic safety.”

ITS applications often include remotely located overhead message boards, road condition and speed zone signs, traffic lights, intersection monitors and collision avoidance systems that require around-the-clock, low-latency network access. The high-bandwidth and industrially-hardened qualities of Red Lion’s RAM RTUs support reliable communication with remote sites – even those that may change in location such as mobile traffic trailers. Also supported is monitoring of multi-service applications that may include video cameras and traffic intersection monitoring. In addition, the rugged characteristics of RAM cellular RTUs support wide temperature ranges and high shock/vibration tolerance to protect against challenging outdoor environments.

Red Lion’s industrial cellular RTUs are ready-to-deploy remote monitoring and control devices that enable customers to reliably connect, monitor and control equipment in industrial environments from nearly any location. RAM industrial cellular RTUs also feature an easy-to-use event engine that can locally trigger I/O or send SMS text messages based on real-time operational data. With multi-carrier 4G LTE support, RAM RTUs provide high-bandwidth communication over cellular networks to allow customers to select the best connectivity for their applications.


• Red Lion products are marketed in Ireland through Instrument Technology.

Monday, 14 September 2015

Support for security conformance scheme!

Tailored Solutions & Consulting, is supporting the ISASecure® IEC 62443 Industrial Cyber Security Conformance Scheme by joining the ISA Security Compliance Institute as a technical member.

Tailored Solutions & Consulting, Inc. (TSC Advantage) is an enterprise security consultancy specializing in the protection of trade secrets, intellectual assets, and other sensitive information. The TSC Advantage approach is a patented and DHS SAFETY Act-designated methodology that holistically optimizes clients’ security posture to suit their unique organizational, procedural and market environments.

ISASecure conformance assessments certify that industrial automation and control systems (IACS) are robust against network attacks and free from known vulnerabilities. ISASecure is a global ISO/IEC 17065 conformance scheme that certifies control systems to IEC 62443 standards.

“We are pleased to add TSC Advantage as a new technical member,” stated Andre Ristaino, ISCI Managing Director. “TSC Advantage expands the diversity of ISCI stakeholders and we welcome their perspective as we grow our certification offerings.”

Tuesday, 22 October 2013

Leader in asymmetric cryptography solutions supports ISA100 wireless std!


Crack Semiconductor, a Canadian-based leader in Public Key or Asymmetric Cryptography Solutions, has joined the ISA100 Wireless Compliance Institute  Focused on security solutions, Crack Semiconductor opted to join ISA100 Wireless after their competitive security analysis recognized the standard’s superior foundational security capabilities.

Crack Semiconductor’s mission is to develop network security processors as specialized components of high-performance security systems. The Crack Zeppelin network security processing platform provides acceleration of the computer-intensive cryptography functions that encrypt and decrypt outgoing and incoming information and protect against intrusion by adversaries.

“Crack Zeppelin is an open standards-based network security processing platform that is completely reprogrammable in both hardware and software. Crack Zeppelin combines embedded, high- performance ARM processing with Crack Semiconductor's advanced cryptographic hardware accelerators on a single chip,” said Art Low, President and CTO, Crack Semiconductor. “We are excited to join the many other global ISA100 WCI members committed to ISA100 Wireless.”
“Security is one of the top user requirements for industrial wireless applications,” said Andre Ristaino, Managing Director, ISA100 Wireless Compliance Institute. “The addition of Crack Semiconductor to ISA100 WCI is a valuable augmentation of security expertise in the ISA100 Wireless technical ecosystem and we look forward to their contribution and commitment.”

Tuesday, 2 April 2013

Managing quality, risk & complience

A new Quality, Risk, and Compliance (QRC) Management System supplier selection guide has been relaesed by ARC Advisory.  The guide includes both selection criteria and guided workflow steps to help in choosing a product quality, risk, and compliance management system for your Enterprise Quality Management operations.

John Blanchard, ARC
QRC solutions on a complexity continuum span low cost solutions with limits on the depth of functionality are provided, to highly functional much higher cost solutions. Different suppliers have also developed special domain expertise in specific industries. Other suppliers have targeted specific small industry sub-segments such as blood banks. Still others have targeted their solutions at small to medium size businesses by offering them through software-as-a-service (SaaS).

The negative impact that defective, contaminated, or off quality products can have on a business is increasing. As the number of incidents and the impact of such incidents continue to increase, governments are responding with increased regulatory requirements. And there is a shift in regulatory response from rapid response and containment of an incident to prevention. This has created a demand for more in-depth QRC system functionality that includes more real-time monitoring and prediction of potential off quality product that extends throughout the manufacturing supply chain. Traditional paper records, manual data entry, and historic data analysis is no longer sufficient. Electronic records, real-time analytics, and more powerful database have become a necessity.

The ARC STAR Supplier Evaluation and Selection Service guides users through a step-by-step process selecting and evaluating suppliers and their products against specific application and industry requirements. The process guides the user through the project and team definition, reviewing and editing ARC-provided selection criteria and supplier questions, weighing selection criteria, developing a supplier Request for Information (RFI) list, evaluating supplier responses, and developing a final ranking of RFI results. ARC STAR then fully documents the process and results for management review and approval. ARC STAR helps ensure inclusive, fact-based, impartial supplier evaluations and selections, free of the user bias issues that typically hamper these activities. In addition, ARC estimates that ARC STAR can reduce the cost and effort of a supplier selection process by well over 50 percent.

The selection guide was authored by John Blanchard. John has been covering all aspects of ensuring product quality and manufacturing regulatory compliance in the manufacturing industries for over 30 years

Wednesday, 5 May 2010

Safety management compliance

New software facilitates process safety management compliance

PAS has released a new version of its comprehensive alarm management and control loop optimisation software with new features to improve plant safety and productivity.

PlantState Suite Version 6.5 provides new features to help improve process safety and to demonstrate good practice in accordance with process safety standards IEC 61511, ISA 84 and compliance with the OSHA 29 CFR 1910.119 rule for plants handling highly hazardous chemicals in the U.S.

To facilitate improved process and plant safety, PlantState Suite Version 6.5 now incorporates the ability to audit and enforce control system parameters when a pre-configured event occurs. This capability provides a mechanism for proving the proper execution of control-system and safety-instrumented-system shutdown routines. It acquires the necessary information automatically, thus precluding the need to manually prove the functionality at a subsequent time.

Change management is another important factor in safety lifecycle management. PlantState Suite Version 6.5 is now integrated with PAS' Integrity(tm) Software, which maps and tracks the configuration of the industry's major control and safety instrumented systems. With this capability, users can access control strategies and change management details in the context of any alarm or event with a single click, thus enabling faster and more accurate troubleshooting.

"Helping our customers to improve their safety and regulatory compliance, while simultaneously improving their bottom line, is PAS' mission. The new capabilities of PlantState Suite Version 6.5 are targeted specifically at these needs," says Chris Lyden, PAS President.