Supporting further growth in aspiration business.

Michael Hall has been recruited to the position of Technical Specialist within Honeywell Security & Fire to support further growth in the FAAST™ Aspirating Smoke Detection (ASD) business.

Michael Hall
Michael’s primary focus is to provide in-depth technical support and training for ASD system design and software to a rapidly growing customer base in EMEA. He brings a wealth of expertise to the role with 18 years electrical engineering experience working for leading fire detection businesses including UTC. Responsibilities have included installation and maintenance, training and support for new product developments.

Tim Checketts, Sales Manager for Speciality Products in EMEA, comments: “Michael joins us at an exciting time; we are seeing further continued growth in our aspiration detection business with new products about to be released and an increase in large scale projects which demand additional levels of technical support and guidance.
“Michael will play a key part in helping customers understand the wide range of applications served by next generation aspiration detection technologies. He is well versed in the needs of today’s fire system integrators and customers and the latest technological innovations. These aspects will enable him to add tangible value to both our business efficiency and customer experience.”

 @Honeywell  #PAuto #EMEA #ASD

Friday, 15 May 2015

Fire safety in waste recycling plants!

Honeywell’s FAAST, a market-leading Aspiration Smoke Detector (ASD), is being implemented by a growing number of recycling and waste management plants. Offering the earliest, most accurate smoke detection, class-leading filtration and system design that removes both dust-stimulated false alarms and problems arising from environmental fluctuation, FAAST provides the highest provision of safety.
Despite the WISH guideline release in 2014, fire events are still highly prevalent. In fact, five fires took place in April alone this year; the Recycling Lives fire in Lancashire on 9th April; the Recycling Lives Preston fire on 10th April; the Ramsey Heights fire in Cambridgeshire on 13th April; the Mangotsfield, Bristol fire on 24th April; and the JSW Waste fire in Salford, Manchester on the 26th April. In fact, Salford experienced two devastating fires in just eight weeks.

ASD technology is growing steadily in popularity; the WISH Guidelines (pdf) recommend its use on page 24 of the report, helping to increase this trend. Honeywell’s FAAST system is now installed in a growing number of recycling and waste management plants, with many more carrying out evaluations.

Tim Checketts, Business Development Manager for Honeywell Fire Safety, comments on the need for effective fire safety in the wake of recent incidents and how firms can negate traditional detection issues, satisfy stringent insurance requirements and reduce the total cost of fire safety. “The WISH Guidelines are helping more sites implement better fire protection, but the incidents in April alone, really do highlight the extreme risks. High dust prevalence and environmental fluctuations that cause increased false alarms demand both high performance and high stability solutions. False alarms lead to disruptions - at least 30 minutes unplanned downtime and resources to investigate per event - and also increase maintenance needs. These combined aspects lead many sites to implement solutions that only meet minimum regulations.

“Regulations and insurance pre-requisites are becoming more stringent, which from a safety perspective is a good thing, but for many firms already under pressure from raised premiums, the implementation of enhanced-safety solutions may seem economically unviable. Choosing a solution like FAAST really can deliver on all levels, while also reducing the total cost of fire safety. Unlike other aspiration solutions, FAAST uses a sophisticated three-stage filtration technique, dual-optics particle analysis and intelligent algorithms that effectively distinguish smoke from dust. FAAST is able to withstand temperature and humidity variations, auto-learning its environment. Integral replaceable components minimise device failure and improve maintenance, which can be costly in hostile environments.

“FAAST is ideal for any facility manager under pressure to guarantee undisrupted and safe operation. We have recently issued a free FAAST Aspiration Smoke Detection Applications Guide, with a detailed section dedicated to recycling and waste management, downloadable from the FAAST website; this provides full information on how FAAST works and why it is the premier solution for these applications.”

Tuesday, 17 February 2015

Aspiration smoke detection applications guide!

Choosing the right fire detection method for a specific environment can have wide-reaching benefits not only in terms of the level of protection provided but also economic advantages such as reduced downtime and improved maintenance.
Aspiration Smoke Detection (ASD) – where air is drawn through sampling holes in a pipe network for smoke particulate analysis – has become one of the premier detection methods in challenging applications, due to its adaptability for diverse applications.

A new in-depth FAAST Aspiration Smoke Detection Applications Guide has been released by Honeywell this month, in order to aid system integrators, consultants, specifiers and installers during the specification, design, installation and commissioning process. The guide details aspiration device benefits and application considerations, along with best practices for installation, commissioning and maintenance. It draws on industry codes of practice and guidance from key associations and focuses on the FAAST Fire Alarm Aspiration Sensing Technology range. Key applications covered include: Telecoms, Large Open Spaces, Extreme Temperature Locations, Dirty Environments, Transportation Facilities, Historic and Cultural Sites, Ducts & Lift Shafts and many more.

Gintare Budriunaite, Marketing Manager, Speciality Products, Honeywell Fire Safety, said: “We developed the guide to provide a detailed, informative resource for anyone interested in learning more about the implementation of Aspiration Smoke Detection in specific environments. It provides particular value to those working in areas where earliest detection is required, interior design aesthetics cannot be compromised, standard detection methods fail, and areas with restricted or limited access. We are seeing significant growth in the use of aspiration technology in these applications and many more for its ability to meet specific challenges.

“Ever-evolving safety standards and insurance prerequisites are driving fire protection to new levels, which is in turn increasing the demand for advanced detection technologies. Next generation ASDs such as FAAST from Honeywell, go one stage further, incorporating state-of-the art technologies designed to deliver the earliest and most accurate fire detection in the most challenging applications, while removing the false alarm issues that plague so many sites and industries.”

Tuesday, 13 July 2010

Smoke detector application

Smoke-detector integrated circuit features ultra-low current consumption and networking capability

The new A5303 from Allegro MicroSystems Europe is a low-current BiCMOS photoelectric smoke detector integrated circuit designed to be used with an infrared optical chamber to sense light scattered from smoke particles.

Key features of the new device include 3 V operation with ultra-low standby current that results in an average 10-year battery life, plus a networking capability that allows units to be interconnected so that if any unit senses smoke all units will sound an alarm. Also included are a latching alarm indicator and a timer function that minimises standby power consumption by controlling the duration of the reduced sensitivity period.

The A5303 incorporates a variable-gain photo-amplifier which can be directly interfaced to an infrared emitter-detector pair. The amplifier gain levels are determined by two external capacitors, and are internally selected depending on the operating mode. Low gain is selected during standby and timer modes. During a local alarm, this low gain is increased (internally) by approximately 45% to provide hysteresis. High gain is used during pushbutton test and to periodically monitor the chamber sensitivity during standby.

The internal oscillator and timing circuitry minimise standby power by sensing for smoke for only 100 µs in every ten seconds. A special three-stage-speedup sensing scheme is incorporated to minimise the time to an audible alarm and also to reduce false triggering. Chamber sensitivity is periodically monitored, with two consecutive cycles of degraded sensitivity required for a warning signal to occur.

The A5303 is supplied in a low-profile (less than 1.2 mm overall height) 20-pin TSSOP package (0.65 mm nominal lead pitch). The package is lead (Pb) free with 100% matt tin lead-frame plating.