Sensor technology detects changes in electric field, in contact, at a distance, through clothing and even through walls
Plessey Semiconductors was awarded a Gold Award at the “Best of Sensors Expo” ceremony at Sensors Expo for its Electric Potential Integrated Circuit (EPIC) sensor technology. The entries were judged on the basis of potential impact, application, distinctiveness, timeliness and availability.
"The nominations demonstrated exceptional innovation, integration and ease of use," said Melanie Martella, Executive Editor of Sensors Magazine, who presented the awards.
16 element array for EPIC |
Michael LeGoff, Plessey Semiconductors’ MD, said, “We are delighted that EPIC technology is being recognised as a truly innovative technology that can be used to create genuinely novel and ingenious products.”
The technology works at normal room temperatures and functions as an ultra high, input impedance sensor that acts as a highly stable, extremely sensitive, contactless digital voltmeter to measure tiny changes in the electric field down to milliVolts. Most places on Earth have a vertical electric field of about 100 Volts per metre. The human body is mostly water and this interacts with the electric field. EPIC technology is so sensitive that it can detect these changes at a distance and even through a solid wall. Thus, for example, in a fire situation, it could be possible to determine if there any people in a smoke filled room before opening the door.
The first EPIC product, the PS25150, is an ultra high impedance, solid state ECG (electrocardiograph) sensor for applications such as non-critical patient monitoring, emergency response diagnostics, sports and health products and will be sampling in September 2011. It can be used as a dry contact ECG sensor without the need for potentially dangerous low impedance circuits across the heart. Key to this is that EPIC detects the voltage change in muscles and nerves without electrical contact so there is no need to have electrodes on or in the body to detect current changes. The resolution available is as good as or better than conventional wet electrodes. The device uses active feedback techniques to both lower the effective input capacitance of the sensing element (Cin) and boost the input resistance (Rin). These techniques are used to realise a sensor with a frequency response suitable for both diagnostic and monitoring ECG applications. The total voltage gain of the system is a function of both the input coupling capacitance (variable) and the internal sensor configuration.
Details of other awardees at the Event!
• The 2012 event: June 6-7, 2012 at the Donald E. Stephens Convention Center in Rosemont, (IL US)
No comments:
Post a Comment