excitation
The new Yokogawa ADMAG AXR is a two-wire magnetic flowmeter that achieves high performance by using dual-frequency excitation technology.
To date, most magnetic flowmeters have been of the four-wire type, where high accuracy and performance are achieved by using a dedicated power-supply cable that is separate from the signal cable used for the measurement current output. The two-wire type, on the other hand, uses just one pair of wires for current output and power supply, offering significantly lower
installation costs by requiring neither a dedicated power supply cable nor a power-supply unit.
installation costs by requiring neither a dedicated power supply cable nor a power-supply unit.
Despite these benefits, conventional two-wire magnetic flowmeters do have limitations in terms of measurement accuracy and stability, and as a result have not been well accepted in the process automation sector.
Now, however, they has developed the dual-frequency excitation technique for minimising electric noise in two-wire models to a level comparable to that of four-wire magnetic flowmeters, thereby achieving the high measurement accuracy and stability needed for use in control loops.
The dual-frequency excitation method uses high-speed digital processing to execute the complex algorithms required to enhance stability and performance while at the same time minimising power consumption.
A further performance enhancement is provided by a new coil configuration. Because a two-wire magnetic flowmeter has a limited power-supply capability, the current supplied to the excitation coil is normally too weak for signals to be differentiated from electrical noise. To resolve this problem, Yokogawa has adopted a new high-density coil construction method that enables a stronger magnetic field to be generated with a low current.
They have also found ways to minimise the noise level by smoothing the inner surface of the measuring tube and developing an electrode that generates very little noise. As a result, the Admag AXR makes it easy to differentiate signals from electrical noise, thereby achieving a measurement accuracy comparable to that of a four-wire magnetic flowmeter.
User friendliness in the new Admag AXR has been enhanced through the addition of a full dot-matrix LCD display capable of displaying messages in six different languages, enabling magnet switches to be operated without opening the cover, the addition of an electrode adhesion diagnosis function, and a design change that allows the orientation of the converter to be changed on site.
The elimination of the need for a dedicated power-supply unit and power-supply cable has allowed a sharp reduction in instrumentation cost. The lower power consumption of the two-wire instrument also reduces running costs.
The Admag AXR is ideally suited to fluid flow measurement in a variety of industries including chemicals, iron & steel, and food & beverages.