Tuesday 7 April 2015

Meeting new immunity testing requirements.

Teseq now offers a testing system that meets the new requirements for immunity testing to low frequency disturbances in the frequency range of 15 Hz to 150 kHz.  The NSG 4060 complies with current testing standards including EN 61326-3-1, IEC 61850-3, IEC 60255-22-7, IEC 60533/IEC 60945, IEC 61000-4-16 and IEC 61000-4-19.

Ideal for use by manufacturers of smart electrical meters, industrial circuit breakers, industrial Ethernet and shipboard equipment, the NSG 4060 is a robust system with extensive features and a best in class user interface with an intuitive front panel that enables the unit to run fully compliant tests without a PC. It accurately tests low frequency immunity in common and differential mode.

The new test system features a full range of verification accessories and ensures compatibility of components at a competitive price.  These accessories allow in-house confidence checking of differential CDN (CDND). 

Disturbances are coupled onto cables in common mode (IEC/EN 61000-4-16) with continuous levels up to 33 V or differential mode (IEC/EN 61000-4-19) with  levels  up to 22 V / 4.5 A. The NSG 4060 features an extension unit that expands the test range to DC and the amplitude to 330 V for short term tests.

This new unit, which combines a signal generator and integrated power amplifier, features a user port for four TTL inputs and four TTL outputs as well as supply voltages for individual monitoring and control applications.  There are also ports for generator output, system and coupling network control as well as phase synchronization input.

A remote control option is available through an optical RS232, RS232, LAN or USB.  Two USB, analog, digital and optical EUT monitoring inputs and external modulation input come standard on each unit.

The NSG 4060 shares the same chassis and user interface as the popular NSG 4070 RF conducted immunity system, featuring the same user-friendly 5.7” color display, superb graphics to enable quick and user-friendly set-up of test procedures, as well as hard keys for important functions.

A user manual with extensive set-up diagrams and instructions is included with each unit.

Technical Specifications

  • Immunity testing to low frequency disturbances in the frequency range of 15 Hz to 150 kHz
  • In compliance with current testing standards including EN 61326-3-1, IEC 61850-3, IEC 60255-22-7, IEC 60533/IEC 60945, IEC 61000-4-16 and IEC 61000-4-19
  • Continuous levels up to 33 V and for IEC 61000-4-19 testing up to 22 V or 4.5 A
  • Optional NSG 4060 extension unit for IEC 61000-4-16 short term tests with DC and amplitudes up to 330 V

No comments:

Post a Comment